×

获取报价

证书查询

顶部

UL817导线连接可靠性测试介绍

文章来源 : 广东三亿体育在线检测 发表时间:2021-10-18 浏览数量:

Conductor Secureness Test是UL817标准中的一个试验项目,意思是导线连接可靠性测试。美规软线组件和电源软线UL817认证需要进行导线连接可靠性测试,接下来为大家介绍UL817导线连接可靠性测试


电线插头UL817-2.jpg


UL817导线连接可靠性测试

依据标准: 

UL817 (81.1, 81.2)


测试对象:

插头的端子( blade,pin)或软线连接器的接触片( female contact)与电线连接好后,模塑或装配到插头或连接器之前。


样品数量: 

Normal: 13 条

Tightened: 20 条

Reduced: 5 条


测试方法:

在电线与端子之间施加一个力(电线大于或等于18AWG时为20磅( 89牛),电线小于18AWG时为8磅( 36牛)),保持1分钟。


判定:

连接处无断裂为合格。


UL817导线连接可靠性测试.jpg


导线连接可靠性测试-UL817标准要求

Conductor Secureness Test

81 .1 If a conductor of a flexible cord is connected to an element (male blade or pin or female contact) of a fitting before the element has been assembled to the fitting, the connection shall not break under a pull applied for 1 minute between the element and the conductor before the element has been assembled into the fittings.  A pull of 20 lbf (89 N) shall be applied if the conductor is No. 1 8 AWG or larger in size.  If a smaller cord is used, the pull shall be 8 lbf (36 N).

81 .1 如果在元件装配到配件上之前,软线的导体已连接到配件的元件(公片或销或母点)上,在元件装配到配件中之前,在元件与导体之间施加1分钟的拉力,该连接不得断开。如果导体是No. 1 8 AWG或更大的尺寸,则应施加20 lbf (89 N)的拉力。如果使用较小的绳,拉力应为8 lbf (36 N)。


81 .2 While the test in 81 .1 is being performed, the angle between the element and the cord conductor is to be the same as in the completely assembled fitting.  The test shall be performed by using dead weights or, at the manufacturer’s option, a power driven tensile testing machine.  If a tensile testing machine is used it shall have jaws suitable for holding the specimen and capable of applying the minimum required tensile load to the specimen while separating at a uniform rate not exceeding 1 inch/minute (25.4 mm/min).  The machine shall be equipped with a scale from which the load can be read to a value of 0.1 lbf (0.4 N). The accuracy of the scale shall be within ±2 % of the value read, and weights shall be provided for calibrating the machine.

81 .2 在进行81 .1中的测试时,元件与芯线导体之间的角度应与完全组装的连接件中相同。测试应使用自重,或根据制造商的选择,使用动力驱动拉力试验机。如果使用拉力试验机,它应该有适合容纳试件的爪,并能够在以不超过1英寸/分钟(25.4毫米/分钟)的均匀速度分离试件时,对试件施加最小所需的拉力载荷。机器应该配备一个刻度,从它可以读出负载的值为0.1 lbf (0.4 N)。刻度的精度应在读取值的±2%以内,并应提供用于校准机器的重量。


三亿体育在线是获得UL TPTDP免目击测试实验室授权的第三方UL检测实验室,实验室具备UL817标准全项测试能力,可提供软线组件和电源软线UL817测试及UL认证服务。


微信咨询检测认证业务

×

获取报价

*公司名称

*您的姓名

*您的手机

*您的需求

为了您的权益,您的信息将被严格保密

在线留言

如果您对我司的产品或服务有任何意见或者建议,您可以通过这个渠道给予三亿体育在线反馈。您的留言三亿体育在线会尽快回复!

姓名:
电话:
公司:
内容:
验证码:
刷新